Calculation: Pressure Peak in Dosing Head at Pressure Stroke

Pressure peak + operating pressure = max. pressure against which the dosing pump must work
Density Chemical Density [kg/dm3] (Water = 1.0)
Q Pump Delivery Capacity [l/h]
F Pump Stroke Frequency [strokes/min]
L Length of Pressure Line [m]
D Diameter of Pressure Line [mm]
Decimal Places
pBeschl Pressure Peak [bar]



The calculation can be used for sinus-like conveying (piston pump with 100% stroke length) only.

Any evaluations and results are based on rough calculations and have to be checked by your own. No guarantee.