The EASYPRO SMART is the successor to the popular EASYPOOL SMART series. Available in two simple pre-configured versions, the water sampling station comes almost ready-touse. The system serves the monitoring and control of various water parameters in your swimming pool. The TOPAX® MCmulti- channel controller installed* in the EASYPRO subjects the water parameters to constant measurement, keeping them in the target range. It works directly in conjunction with the peristaltic pumps installed in the water sampling station. Additional actuators can be actuated. Automatic continuous recording of the water parameters and depiction of their development permit simple diagnosis.
- TOPAX® MC multi-channel controller
- Peristaltic pumps
- Measuring cell fittings
- Flow control
- Flow adjustment valve
- Sampling water extraction point
- Temperature sensor
- Inflow and outflow tap
- Buffer solutions for adjusting the measuring cells
- Suction lines (not installed on the baseplate)
- Injection nozzles (not installed on the baseplate)
- The measuring cells are partially packaged separately and not pre-installed.
EASYPRO SMART components (fitted on the baseplate)
For more information please visit our website www.topax-mc.de/en
More product views
EASYPRO SMART for swimming pools | CP | RP | CPL | Dimensions (W x H x D) | mm | 454 x 465 x 167 approx. | ||||
---|---|---|---|---|---|---|---|---|---|---|
Sample water requirement | l/h | 45 approx. | ||||||||
Sample water infl ow and discharge | Stop valve with hose clamp connector 6/8 | |||||||||
Pressure resistance | bar | max. 3 | ||||||||
Pressure loss in the water sampling station | bar | 0.3 approx. | ||||||||
Voltage supply | 100 – 240 V AC, 50/60 Hz | |||||||||
Power consumption | W | max. 30 | ||||||||
Analogue outputs for remote transmission | 4 x 0/4 – 20 mA, working resistance max. 500 Ω | |||||||||
Disturbance variable input | mA | 0/4 – 20 | ||||||||
Interfaces | Ethernet TCP/IP or RS485 Modbus RTU (optional) | |||||||||
Protection class | IP65 (electronic controller) | |||||||||
Ambient temperature | °C | -5 to +45 (no exposure to direct sunlight) | ||||||||
Control characteristic | P, PI, PID or PD behaviour, control direction selectable with distur-bance variable feed forward, 2-side control selectable | |||||||||
Measuring inputs (depending on version) | ||||||||||
Number of measuring inputs | 2a | 3b | ||||||||
Free chlorine | CS120 excess chlorine measuring cell | mg/l | 0 – 15c | - | 0 – 15c | |||||
pH value | pH single-rod measuring cell | pH | 2 – 12d or 0 – 14d | |||||||
Redox value | Redox single-rod measuring cell | mV | - | 0 – 1000 | - | |||||
Conductivity conductive | Conductivity measuring cell (k=1) | mV | - | 0 – 2e, 0 – 20e or 0 – 100e |
||||||
Temperature | Pt100 | °C | 5 – 45 | |||||||
Output modules (depending on version) | ||||||||||
Number of output modules | up to 4 | |||||||||
Servomotor relay | 2 x 230 V AC, 5 A (ohmic load) | |||||||||
kΩ | Potentiometer feedback: 1 – 10 | |||||||||
Servomotor 20 mA | Constant 0/4 – 20 mA output | |||||||||
Servomotor with 20 mA feedback | ||||||||||
Relay | 2 x 230 V AC, 5 A (ohmic load) | |||||||||
Optocoupler | 2 x 80 V DC, 5 mA |
a) A temperature sensor can also be connected.
b) Additionally, up to two temperature sensors can be connected.
c) Dependant on the measuring cell transconductance.
d) Depandant on the single-rod measuring cell.
e) Corresponds to 0 - 5 % salt content.
Subject to technical changes.
-
Operating instructions
- EASYPRO SMART
- EASYPRO SMART
- EASYPRO SMART
- EASYPRO SMART
Product information
Lutz-JESCO America Corp.
55 Bermar Park
Rochester, NY 14624
Toll-Free: +1-800-554-2762
Fax: +1-585-426-4025
mail@jescoamerica.com
Outside the U.S.
Tel.: +1-585-426-0990